50multimode-outdoor-loose-tube-cables50/125µm StratusClear Multimode Loose Tube Outdoor Cables

Hitachi Bulk Fiber, 12 through 432 Fiber, 50/125µm Multimode OM2, OM3, 50/125 µm Stratus Clear Multimode, RoHS compliant0/125 µm Multimode Loose Tube Cable

Bulk Outdoor Fiber Optic Cable

  • UV Resistant Jacket
  • Gel Filled Loose Tubes Provide Protection Against Water Penetration
  • Dry, Super Absorbent Polymers (SAPs) Eliminate Water Migration in Cable Interstices
  • Suitable for Lashed Aerial, Duct, Underground Conduit Applications

50/125 µm Multimode Loose Tube Outdoor Cable

Part No.

Fibers
per
Tube

Fiber Count

Tube Layout

Cable OD
in (mm)

Maximum
Load Install
lbs-f (N)

Operation
lbs-f (N)

Weight
lbs/1000ft (kg/1000m)

OM2 - 50/125 µm Multimode Cable (50/125/250)

60282-12

2

12

6xCSM

.493 (12.5)

600 (2670)

200 (890)

74.0 (110.3)

60282-24

2

24

12xCSM

.700 (17.8)

600 (2670)

200 (890)

160.0 (238.4)

60408-24

4

24

6xCSM

.493 (12.5)

600 (2670)

200 (890)

75.0 (111.8)

60408-48

4

48

12xCSM

.700 (17.8)

600 (2670)

200 (890)

160.0 (238.4)

60087-18

6

18

5xCSM

.463 (11.7)

600 (2670)

200 (890)

56.0 (83.4)

60087-24

6

24

5xCSM

.463 (11.7)

600 (2670)

200 (890)

60.0 (89.4)

60087-36

6

36

6xCSM

.493 (12.5)

600 (2670)

200 (890)

75.0 (111.8)

60087-48

6

48

8xCSM

.561 (14.2)

600 (2670)

200 (890)

97.0 (144.5)

60088-12

12

12

5xCSM

.463 (11.7)

600 (2670)

200 (890)

48.0 (71.5)

60088-24

12

24

5xCSM

.463 (11.7)

600 (2670)

200 (890)

52.0 (77.5)

60088-36

12

36

5xCSM

.463 (11.7)

600 (2670)

200 (890)

56.0 (83.4)

60088-48

12

48

5xCSM

.463 (11.7)

600 (2670)

200 (890)

60.0 (89.4)

60088-60

12

60

5xCSM

.463 (11.7)

600 (2670)

200 (890)

64.0 (95.4)

60088-72

12

72

6xCSM

.493 (12.5)

600 (2670)

200 (890)

76.0 (113.2)

60088-84

12

84

7xCSM

.552 (14.0)

600 (2670)

200 (890)

93.0 (138.6)

60088-96

12

96

8xCSM

.581 (14.8)

600 (2670)

200 (890)

106.0 (157.9)

60088-108

12

108

9xCSM

.620 (15.7)

600 (2670)

200 (890)

120.0 (178.8)

60088-120

12

120

10xCSM

.649 (16.5)

600 (2670)

200 (890)

137.0 (204.1)

60088-132

12

132

11xCSM

.683 (17.3)

600 (2670)

200 (890)

153.0 (228.0)

60088-144

12

144

12xCSM

.720 (18.3)

600 (2670)

200 (890)

171.0 (255.0)

60088-168

12

168

12x6xCSM

.737 (18.7)

600 (2670)

200 (890)

143.0 (213.1)

60088-192

12

192

12x6xCSM

.737 (18.7)

600 (2670)

200 (890)

151.0 (225.0)

60088-216

12

216

12x6xCSM

.737 (18.7)

600 (2670)

200 (890)

159.0 (236.9)

60088-240

12

240

13x7xCSM

.770 (19.6)

600 (2670)

200 (890)

175.0 (260.8)

60088-264

12

264

14x8xCSM

.805 (20.4)

600 (2670)

200 (890)

196.0 (292.0)

60088-288

12

288

15x9xCSM

.835 (21.2)

600 (2670)

200 (890)

213.0 (317.4)

60088-312

12

312

16x10xCSM

.870 (22.1)

600 (2670)

200 (890)

233.0 (347.2)

60088-336

12

336

17x11xCSM

.902 (22.9)

600 (2670)

200 (890)

255.0 (380.0)

60088-360

12

360

18x12x6xCSM

.956 (24.3)

600 (2670)

200 (890)

241.0 (359.1)

60088-384

12

384

18x12x6xCSM

.956 (24.3)

600 (2670)

200 (890)

249.0 (371.0)

60088-432

12

432

18x12x6xCSM

.956 (24.3)

600 (2670)

200 (890)

266.0 (396.3)

50/125 µm Multimode StratusClear Loose Tube Outdoor Cable

Part No.

Fibers
per
Tube

Fiber Count

Tube Layout

Cable OD
in (mm)

Maximum
Load Install
lbs-f (N)

Operation
lbs-f (N)

Weight
lbs/1000ft (kg/1000m)

OM3 - 50/125 µm StratusClear Multimode Cable (50/125/250)

60938-12

2

12

6xCSM

.493 (12.5)

600 (2670)

200 (890)

74.0 (110.3)

60938-24

2

24

12xCSM

.700 (17.8)

600 (2670)

200 (890)

160.0 (238.4)

60939-24

4

24

6xCSM

.493 (12.5)

600 (2670)

200 (890)

75.0 (111.8)

60939-48

4

48

12xCSM

.700 (17.8)

600 (2670)

200 (890)

160.0 (238.4)

60940-18

6

18

5xCSM

.463 (11.7)

600 (2670)

200 (890)

56.0 (83.4)

60940-24

6

24

5xCSM

.463 (11.7)

600 (2670)

200 (890)

60.0 (89.4)

60940-36

6

36

6xCSM

.493 (12.5)

600 (2670)

200 (890)

75.0 (111.8)

60940-48

6

48

8xCSM

.561 (14.2)

600 (2670)

200 (890)

97.0 (144.5)

60943-12

12

12

5xCSM

.463 (11.7)

600 (2670)

200 (890)

48.0 (71.5)

60943-24

12

24

5xCSM

.463 (11.7)

600 (2670)

200 (890)

52.0 (77.5)

60943-36

12

36

5xCSM

.463 (11.7)

600 (2670)

200 (890)

56.0 (83.4)

60943-48

12

48

5xCSM

.463 (11.7)

600 (2670)

200 (890)

60.0 (89.4)

60943-60

12

60

5xCSM

.463 (11.7)

600 (2670)

200 (890)

64.0 (95.4)

60943-72

12

72

6xCSM

.493 (12.5)

600 (2670)

200 (890)

76.0 (113.2)

60943-84

12

84

7xCSM

.552 (14.0)

600 (2670)

200 (890)

93.0 (138.6)

60943-96

12

96

8xCSM

.581 (14.8)

600 (2670)

200 (890)

106.0 (157.9)

60943-108

12

108

9xCSM

.620 (15.7)

600 (2670)

200 (890)

120.0 (178.8)

60943-120

12

120

10xCSM

.649 (16.5)

600 (2670)

200 (890)

137.0 (204.1)

60943-132

12

132

11xCSM

.683 (17.3)

600 (2670)

200 (890)

153.0 (228.0)

60943-144

12

144

12xCSM

.720 (18.3)

600 (2670)

200 (890)

171.0 (255.0)

60943-168

12

168

12x6xCSM

.737 (18.7)

600 (2670)

200 (890)

143.0 (213.1)

60943-192

12

192

12x6xCSM

.737 (18.7)

600 (2670)

200 (890)

151.0 (225.0)

60943-216

12

216

12x6xCSM

.737 (18.7)

600 (2670)

200 (890)

159.0 (236.9)

60943-240

12

240

13x7xCSM

.770 (19.6)

600 (2670)

200 (890)

175.0 (260.8)

60943-264

12

264

14x8xCSM

.805 (20.4)

600 (2670)

200 (890)

196.0 (292.0)

60943-288

12

288

15x9xCSM

.835 (21.2)

600 (2670)

200 (890)

213.0 (317.4)

60943-312

12

312

16x10xCSM

.870 (22.1)

600 (2670)

200 (890)

233.0 (347.2)

60943-336

12

336

17x11xCSM

.902 (22.9)

600 (2670)

200 (890)

255.0 (380.0)

60943-360

12

360

18x12x6xCSM

.956 (24.3)

600 (2670)

200 (890)

241.0 (359.1)

60943-384

12

384

18x12x6xCSM

.956 (24.3)

600 (2670)

200 (890)

249.0 (371.0)

60943-432

12

432

18x12x6xCSM

.956 (24.3)

600 (2670)

200 (890)

266.0 (396.3)

Loose Tube Outdoor Cable Applications

  • Suitable for Lashed Aerial, Duct, Underground Conduit Applications
  • Conventional Outside Plant Fiber Optic Cable for Video Security, Datacom, Broadcast, Telecom or Campus Backbone Applications
  • Outstanding Loss Consistency Across a Wide Range of Temperatures - Good for High Altitude Telescope Arrays, Underground Scientific Experiment Measurements Etc...

Loose Tube Outdoor Cable Optical Specifications

TIA/EIA-568-B.3/B.3-1
ISO/IEC 11801, 2nd Edition
Bellcore GR-20-CORE

 

50/125 µm Multimode
(OM2)

StratusClear 50/125 µm Multimode
(OM3)

Maximum Attenuation

≤3.25 dB/km @ 850 nm
≤1.0 dB/km @ 1300 nm

≤3.0 dB/km @ 850 nm
≤1.0 dB/km @ 1300 nm

Minimum Bandwidth (OFL)

500 MHz/km @ 850 nm
500 MHz/km @ 1300 nm

1500 MHz/km @ 850 nm
500 MHz/km @ 1300 nm

Minimum Bandwidth (RML)

510 MHz/km @ 850 nm
n/a

1400 MHz/km @ 850 nm
n/a

Gigabit Ethernet Support Distance

600 m @ 850 nm
600 m @ 1300 nm

1000 m @ 850 nm
1000 m @ 1300 nm

10 Gigabit Ethernet Support Distance

n/a
n/a

300 m @ 850 nm
n/a

Loose Tube Outdoor Cable Mechanical Specifications

  • Bend Radius, No Load = 10x Cable Overall Diameter
  • Bend Radius, Load = 20x Cable Overall Diameter

Online Store

Home
Distribution, Brands
   Hitachi Cable
   Optical Cable Corp.
   Hellermann Tyton
   Paladin Tools
   Fluke Networks
   Tripplite
   OnQ Legrand
   Coleman
   Bogen
   Winston
   Lutron
   AFL Telecommunications
Cable Manufacturing
Standard Cables
Custom Cables
   Modular Assemblies
   Telco Cables
   Fiber Optic Cables
   Military Cables
   Coaxial Cables
   CISCO Cables
   Nortel Cables
   HP Cables
   Serial / Parallel
Our Team
Cables Specials
Request a Quote
Contact Us

E-Mail

surplus
HCM_Hitachi_Cable
tripp-lite-lg
onq-legrand-lg
fluke-networks-lg
afl-telecommunications-lg
smp-lg



Buy Cables Online

E-Mail or Call us today at 888-213-5465 with your requirements

Home | Distribution, Brands | Hitachi Cable | HCM - Hitachi Cable Manchester Products | Hitachi Indoor Outdoor Fiber | Tight Buffered Multimode 50 125 | Tight Buffered Multimode 62.5 125 | Tight Buffered Singlemode | Hitachi Outside Plant Fiber | Armored Singlemode | Armored Multimode | Loose Tube 50 125 Multimode | Loose Tube 62.5 125 Multimode | Loose Tube Singlemode | Optical Cable Corp. | OCC Fiber Cables | Hellermann Tyton | Hellermann Tyton Products | Paladin Tools | Paladin Tools Products | Paladin Tools CrimpAll | Paladin AMP / Tyco Crimper | Paladin Tools Tone & Probe | Fluke Networks | Fluke Networks Products | Fluke Datacomm Cabling | Fluke IT Networking | Fuke Telecom | Fluke Micromapper | Fluke Intellitone | Tripplite | Tripplite Products | Tripplite Power Supplies | Tripplite UPS | Tripplite Surge Suppressors | Tripplite Surge Protection | Tripplite PDU | Tripplite UPS Batteries | Tripplite KVM | Tripplite Cables | OnQ Legrand | OnQ Legrand Products | OnQ Home Entertainment | OnQ Home Communications | OnQ Home Comfort | OnQ Structured Wiring | onq-legrand-catalog | Coleman | Coleman Precision Video Coax | Coleman CCTV Coax | Coleman CATV Coax | Bogen | Mixer Amplifiers | Power Amplifiers | Power Vector Mixer | Wireless Microphones | Apogee Near Speakers | Cone Speakers | Horn Speakers | Foreground Speakers | Music Input Sources | Telephone Paging | Self Amplified Paging | Voice over IP Gateways | Office Communications | Enhancement Systems | Special Electronics | Bogen Accessories | Winston | Lutron | Lutron Sivoia Products | Lutron Power Products | AFL Telecommunications | Cable Manufacturing | Standard Cables | Custom Cables | Modular Assemblies | Telco Cables | Fiber Optic Cables | Military Cables | Coaxial Cables | CISCO Cables | Nortel Cables | HP Cables | Serial / Parallel | Our Team | Cables Specials | Request a Quote | Contact Us |

 

 

 

© Copyright, 2010, Nu-Tek Inc. All rights reserved
 

advert
click here
advert